Products
AortaAIM
AortaAIM measures the aorta on CT, region by region, for physician review.
Measurements for review by qualified physicians.
AortaAIM is not CE marked and is not available for sale.
Example output
The whole aorta, region by region
Every region of the aorta, measured the same way.

- Max diameter
- 38.5 mm
- Orthogonal diameter
- 34.5 mm

- Max diameter
- 38.0 mm
- Orthogonal diameter
- 37.0 mm

- Max diameter
- 35.0 mm
- Orthogonal diameter
- 33.0 mm

- Max diameter
- 35.0 mm
- Orthogonal diameter
- 32.5 mm

- Max diameter
- 29.5 mm
- Orthogonal diameter
- 27.5 mm

- Max diameter
- 29.5 mm
- Orthogonal diameter
- 26.0 mm

- Max diameter
- 25.0 mm
- Orthogonal diameter
- 22.5 mm

- Max diameter
- 20.5 mm
- Orthogonal diameter
- 19.5 mm

- Max diameter
- 19.0 mm
- Orthogonal diameter
- 18.0 mm

- Max diameter
- 20.0 mm
- Orthogonal diameter
- 16.5 mm

- Max diameter
- 13.0 mm
- Orthogonal diameter
- 11.5 mm

- Max diameter
- 13.0 mm
- Orthogonal diameter
- 11.5 mm

All measurements
| Region | Max diameter | Orthogonal diameter |
|---|---|---|
| R1 Aortic root | 38.5 mm | 34.5 mm |
| R2 Ascending thoracic aorta | 38.0 mm | 37.0 mm |
| R3 Distal ascending aorta | 35.0 mm | 33.0 mm |
| R4 Mid transverse arch | 35.0 mm | 32.5 mm |
| R5 Isthmus | 29.5 mm | 27.5 mm |
| R6 Descending thoracic aorta | 29.5 mm | 26.0 mm |
| R7 Mesenteric segment | 25.0 mm | 22.5 mm |
| R8 Renal segment | 20.5 mm | 19.5 mm |
| R9 Infrarenal segment | 19.0 mm | 18.0 mm |
| R10 Aortic bifurcation | 20.0 mm | 16.5 mm |
| R11 Left proximal common iliac artery | 13.0 mm | 11.5 mm |
| R12 Right proximal common iliac artery | 13.0 mm | 11.5 mm |
Example output on a public CT (TotalSegmentator, Wasserthal et al., CC BY 4.0). Pre-market software, not for clinical use.
Why it matters
The same measurement, every time
Manual reports often record one to three levels. AortaAIM measures the whole aorta, for the physician to review.
Standardised
The same landmarks and the same method on every study.
Complete
Twelve regions, from the aortic root to the iliac arteries.
Checkable
Every value can be checked against the image it came from.
How it fits
From CT to PACS, with no new viewer
Results arrive in PACS, where radiologists already read.
CT
A finished scan is sent on from PACS.
AortaAIM
The aorta is measured, region by region.
PACS
Results come back for physician review.
What comes next
Every vessel. Every body. Every modality.*
*In development. Not part of the current version and not available.